[. . . ] During the next cooling phase this channel is heated by hot gas and the water evaporates. If no thermal termination occurs, the defrosting phase is ended after 25 minutes (see chap. After 2 minutes of drip-off time plus another 4 minutes (due to minimum compressor off time c2 = 6), the compressor will start up again. The evaporator fan will start up again 5 minutes after the compressor start. [. . . ] Plinth panel - Remove fastening screws (red arrow) on the upper side of the plinth panel. - Pull the panel slightly forwards and then upwards (it is hooked in at the bottom). 1/1) - Turn the fan cover clock wise to the right and lift off downwards. -Pull evaporator sensor out of the collection pan (position described below). -Cable is directly connected to the electronic controller in the plinth panel. -Sensors are directly connected to the electronic controller in the plinth panel. Remove Evaporator fan - Disconnect the cable at the back and pull it through into the interior. - Disconnect the cables at the back and pull through the rear wall into the interior. Remove Main adaptor: - Remove two pcs screws and take out main adaptor. Remove Transformer: - Remove 1pcs screw (red arrow) and take out transformer. - Take hold of the seal at the bellows or magnetic strip and gently move it to and fro to draw it out of the door frame. - Then press the seal completely into the groove all along the door frame. NOTE: The dart profile of the seal must be completely "hooked into" the groove. Draw the bellows slightly to one side and check the correct position of the seal all the way round. - With FDv 4613 remove the fastening screws and pulls the display upwards. - Take hold of the cables at the cable lugs using long-nosed pliers and pull them out of the connector. - Remove stoppers and fastening screws on the upper side of the plinth panel. - Pull the panel slightly forwards and then upwards (it is hooked in at the bottom) (Fig. Dismounting the door: - Remove the inner fastening screw(red arrow) of the lower turn hinge. - Prepare the heater cable so that it can be pulled downwards through the turn hinge. - Hold the turn hinge with pliers (pre-tensioning of the torsion rod) and loosen both the outer screws. NOTE: The turn hinge must be positioned so that when mounting the door in closed condition there is a pre-tension of at least 90°. [. . . ] - Press and hold down the "Defrost" button for five seconds -> "rES" will appear in the display. - Press the "Mute "and "Set" button simultaneously for more than 5 seconds until the display show "0" to access parameter. - Press the "Light" button repeatedly until the display show "17" (password) and then press "Set". -Use the "Light" or the "Defrost" button to select the parameters. [. . . ]